<LOGO>
FM Transmitter Measurement Report
Created: 2024-03-24 01-35-28
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
100.20 MHz 3/5, 36 dBuV INTER
Pilot RDS Phase Difference
7.2 kHz 2.9 kHz -50 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
21 kHz 26 kHz 5968 0,0000
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,2 dBr
MIN AVE MAX % above 10,2 dBr
1,1 dBr 2,13 dBr 3,9 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" INTER " F201 0 (No PTY) 1 0 1 1 1:35, 24.03.2024
RT
"LA LIBRAIRIE FRANCOPHONE - FRANCE INTER 1ERE RADIO DE FRANCE "
AF EON
92.6, 94.6, 94.9, 99.2, 99.9, 100.2 MHz F202, F206, F203, F209
FM Scope Station: 100.20 MHz, signal: 3/5 (36 dBuV) Max at: 26 kHz MIN: 21 kHz % above 75 kHz: 0,0000 Acquired: 2024/03/24 1:34:25 Total samples: 5968 Equivalent time: 0:04:58 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200 300
FM Scope MAX: 3,9 dBr MIN: 1,1 dBr AVE: 2,13 dBr % above 10,2 dBr: 0,0 Last value: 1,7 dBr (2024/03/24 1:34:24) Station: 100.20 MHz, signal: 4/5 (36 dBuV) 01:22 01:24 01:26 01:28 01:30 01:32 01:34 0 50 100 Dev. MAX [kHz] 0 2 4 Pm [dBr] 0 5 Signal Quality